Annals of Surgical Oncology Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

10.1245/ASO.2005.04.028
Annals of Surgical Oncology 12:570-573 (2005)
© 2005 Society of Surgical Oncology
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Di Carlo, I.
Right arrow Articles by Cordio, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Di Carlo, I.
Right arrow Articles by Cordio, S.

Original Article

External Jugular Vein Cutdown Approach, as a Useful Alternative, Supports the Choice of the Cephalic Vein for Totally Implantable Access Device Placement

Isidoro Di Carlo, MD, PhD1, Francesco Barbagallo, MD1, Adriana Toro, MD1, Maria Sofia, MD, Rosario Lombardo, MD1 and Stefano Cordio, MD2

1 Department of Surgical Sciences, Organ Transplantation and Advanced Technologies, University of Catania, Cannizzaro Hospital, Via Messina, 829, 95126 Catania, Italy
2 Department of Oncology, Garibaldi Hospital, 95100 Catania, Italy

Correspondence: Address correspondence and reprint requests to: Isidoro Di Carlo, MD, PhD; E-mail: idicarlo{at}unict.it

Background: Cephalic vein (CV) cut down for totally implantable venous access device (TIVAD) placement has been accepted as an alternative to the percutaneous subclavian vein approach. The aim of this retrospective study was to validate the external jugular vein (EJV) cut-down approach when the CV is not feasible.

Methods: Patients receiving a TIVAD from January 1995 to December 2003 were included in this study. Age, sex, surgical technique, disease, device used, length of the procedure, and morbidity were considered.

Results: A total of 427 TIVADs were placed in 425 patients: 253 men (59.5%) and 172 women (40.5%) aged 31 to 79 years. Of 425 patients, 5 were excluded; 420 underwent a CV cut down on the first attempt, and 391 (93.1%) procedures were successful. Among the final 29 patients, 20 (68.96%) underwent a TIVAD placement through the ipsilateral EJV cut-down approach. In the remaining nine patients (31.04%), TIVAD placement was performed through the ipsilateral internal jugular vein in four cases, via the ipsilateral axillary vein in three cases, and through the ipsilateral coracobrachial vein in the other cases. No immediate postoperative complications were detected in any of the patients.

Conclusions: TIVAD placement by the CV cut-down approach is safe and fast, and its success rate is very high. By avoiding the immediate complications associated with the percutaneous approach, the EJV cut down has to be considered a valid, safe, and suitable alternative when the CV is not feasible.

Key Words: Totally implantable venous access device • Chronic indwelling central venous access • Venous access • Cephalic vein • Internal jugular vein




This article has been cited by other articles:


Home page
Ann OncolHome page
R. Biffi, F. Orsi, S. Pozzi, U. Pace, G. Bonomo, L. Monfardini, P. Della Vigna, N. Rotmensz, D. Radice, M. G. Zampino, et al.
Best choice of central venous insertion site for the prevention of catheter-related complications in adult patients who need cancer therapy: a randomized trial
Ann. Onc., May 1, 2009; 20(5): 935 - 940.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the Society of Surgical Oncology.